The short version of Stenabolic fits in a sentence. The long version — which is the one that helps — is below.
Reviewed 2025-11-05. Anything still debated is marked as such rather than presented as settled.
SR9009 is a synthetic small molecule studied as a REV-ERB agonist. REV-ERBα and REV-ERBβ are nuclear receptors that help regulate circadian rhythms and metabolic gene expression. The compound was identified in academic screening efforts to find synthetic ligands for these receptors. In cell and animal studies, SR9009 alters transcription of genes involved in lipid and glucose metabolism, and it can shift circadian behavior. It is not an approved therapeutic agent.
Mechanistically, SR9009 binds the ligand-binding domain of REV-ERBα/β and enhances recruitment of corepressor complexes. This represses target genes rather than activating them. Because REV-ERB proteins normally compete with ROR proteins at shared response elements, the net effect depends on tissue and timing. Researchers use SR9009 to probe how nuclear receptor signaling links the clock to metabolism, inflammation, and muscle biology. Findings are largely preclinical, and the precise contribution of each receptor subtype remains under study.
SR9009 is frequently discussed in fitness and research-chemical contexts, yet it has no approved medical indication. Regulatory agencies have not authorized it for human use, and it is not a standard prescription drug. Some sports organizations list it as a prohibited substance because of its potential performance-enhancing properties. Published human data are sparse, so claims about its effects in people often rely on animal models or anecdotal reports. Quality and identity of online materials can vary widely.
REV-ERB proteins typically suppress gene expression by recruiting corepressor complexes to DNA response elements. SR9009 binds these receptors and strengthens that repressive action in cell-based assays. Studies in rodents have reported changes in lipid handling, mitochondrial function, and exercise capacity after treatment. Such findings are often cited as evidence for metabolic effects, but species differences and limited pharmacokinetic data make direct translation to humans uncertain. Researchers continue to examine which effects are robust and which depend on specific experimental conditions.
SR9009 is frequently discussed alongside other REV-ERB ligands, including synthetic agonists and natural heme-related molecules. Its selectivity for REV-ERB over related nuclear receptors has been measured in binding and reporter assays, though off-target activity at higher concentrations is possible. The compound is prohibited in sport by the World Anti-Doping Agency, and it is not approved for any medical use in major jurisdictions. Products sold online may be labeled as research chemicals, and their identity and purity are not guaranteed by regulatory review.
| Property | Value | Notes |
|---|---|---|
| Chemical class | Synthetic REV-ERB agonist | Small-molecule ligand; not a hormone or peptide |
| Molecular formula | C20H24ClN3O4S | Reported for the free base |
| CAS Registry Number | 1379686-30-2 | Unique chemical identifier |
| Common synonyms | SR9009; stenabolic | Stenabolic is informal and not an official name |
| Reported targets | REV-ERBα and REV-ERBβ | Nuclear receptors linked to circadian and metabolic regulation |
Analytical identification of SR9009 typically relies on liquid chromatography coupled with tandem mass spectrometry. In biological samples, researchers first separate the compound from matrix components using protein precipitation, liquid-liquid extraction, or solid-phase extraction. High-performance liquid chromatography with ultraviolet detection and nuclear magnetic resonance spectroscopy can support structural confirmation of reference materials. Because SR9009 is a small, relatively lipophilic molecule, reverse-phase columns and acidic mobile phases are common. Laboratories often include isotope-labeled internal standards to improve quantification and to correct for ion suppression.
Stability depends on physical form, temperature, light exposure, and solvent. Solid SR9009 is generally stored cold and dry, with protection from light to limit degradation. Dimethyl sulfoxide stocks are common for laboratory work, but repeated freeze-thaw cycles can reduce compound integrity. Aqueous solutions may be less stable than organic stocks, and the ethyl ester in the structure can be susceptible to hydrolysis under certain conditions. Researchers typically validate storage conditions and recheck purity before quantitative experiments, especially when using archived material.
Regulatory treatment of SR9009 varies by country and region. It is not approved as a pharmaceutical, and several jurisdictions restrict its sale for human consumption. Some authorities classify it as a research chemical, a prescription-only substance, or a prohibited performance-enhancing agent in sport. Purchasers may encounter certificates of analysis, but these documents do not guarantee identity, purity, or legality. In research settings, institutional safety reviews and controlled procurement help ensure that materials are handled under appropriate oversight. The absence of harmonized rules means that legal status can change and requires verification.
Analytical chemists detect SR9009 with liquid chromatography-tandem mass spectrometry, commonly abbreviated LC-MS/MS. Sample preparation may involve protein precipitation, liquid-liquid extraction, or solid-phase extraction before analysis. Laboratories can target the parent compound or its metabolites, depending on the matrix and the purpose of testing. Anti-doping methods require sensitive and specific assays because concentrations in biological samples can be low. Reference standards and validated methods are essential for reliable identification and quantification.
Regulatory agencies have not approved SR9009 for human therapeutic use. It is typically sold as a research chemical with labels stating that it is not for human consumption. The World Anti-Doping Agency prohibits the substance in sport, generally under the category of non-approved substances. Customs and national laws may restrict importation, sale, or possession. Product quality and legal status can vary by country and vendor, and therapeutic claims are not permitted in regulated advertising because the compound lacks approval.
Several misconceptions surround SR9009. It is often described as a SARM, a steroid, or an exercise pill, but its known target is the REV-ERB receptor family. Rodent studies have examined exercise capacity and metabolic markers, yet human outcomes remain unproven. Oral bioavailability appears low in animals, and human pharmacokinetics are not well characterized. Online products may contain impurities or different compounds, so identity and purity testing are important for research use.
In laboratory settings, SR9009 is commonly identified by its molecular structure and its interaction with REV-ERB receptors. Vendors may list it under synonyms such as Stenabolic or REV-ERB agonist, but those names do not define purity or identity. Analytical confirmation typically uses high-performance liquid chromatography with ultraviolet detection or liquid chromatography–mass spectrometry. A reference standard is needed to compare retention time and mass spectrum, because the compound can be confused with related research chemicals.
Handling practices for SR9009 focus on minimizing degradation and contamination. The solid is generally stored desiccated at or below -20 °C, protected from light and moisture. Stock solutions are often prepared in dimethyl sulfoxide or ethanol, then aliquoted to avoid repeated freeze–thaw cycles. Aqueous solubility is low, so formulations for animal studies may require cosolvents or suspending agents. Personnel should follow institutional chemical safety procedures, because toxicological data for humans are incomplete.
=== Substrates === Norepinephrine Substrate-type norepinephrine releasing agents (e.g., ephedrine, amphetamine) Catecholaminergic activity enhancers (e.g., selegiline, PPAP, BPAP) Certain noradrenergic neurotoxins (e.g., DSP-4, xylamine)
Replacement of the phenyl portion of the phenethyl group by any monocycle, whether or not further substituted in or on the monocycle; substitution in or on the phenethyl group with alkyl, alkenyl, alkoxyl, hydroxyl, halo, haloalkyl, amino or nitro groups; substitution in or on the piperidine ring with alkyl, alkenyl, alkoxyl, ester, ether, hydroxyl, halo, haloalkyl, amino or nitro groups; replacement of the aniline ring with any aromatic monocycle whether or not further substituted in or on the aromatic monocycle; and/or replacement of the N-propionyl group by another acyl group."
=== Interfering chromogens === The nonspecificity of Jaffe's reaction causes falsely elevated creatinine results in the presence of protein, glucose, acetoacetate, ascorbic acid, guanidine, acetone, cephalosporins, aminoglycosides (mainly streptomycin), ketone bodies, α-keto acids, and other organic compounds. Ammonium is also an interferent; if the sample is plasma, care needs to be taken that ammonium heparin has not been used as an anticoagulant. Nonspecificity is markedly decreased in urine samples since urine creatinine levels are much higher than blood and it generally does not contain significant levels of interfering chromogens. The Jaffe reaction's nonspecificity remains an important issue. Diabetes patients are a high-risk population to develop chronic kidney disease (CKD) and, therefore, interferences from glucose and acetoacetate are of particular importance. Artifacts such as hemolysis, lipemia, and icteremia can also affect accuracy. Hemolysis releases Jaffe-reacting chromogens and therefore will falsely increase results. Lipemia and icteremia can inhibit optical readings and falsely decrease values. The procedure has been developed over time with the intention to minimize these interferents.
It has a six-person board appointed by the European Council, on the Council's recommendation. The president of the council and a commissioner can sit in on ECB meetings, but do not have voting rights.
Sources: en.wikipedia.org
Therefore, the feedback that is read by this central regulator could include chemical and mechanical as well as cognitive cues. The significance of each of these factors will depend on the nature of the fatigue-inducing work that is being performed. Though not universally used, "metabolic fatigue" is a common alternative term for peripheral muscle weakness, because of the reduction in contractile force due to the direct or indirect effects of the reduction of substrates or accumulation of metabolites within the myocytes. This can occur through a simple lack of energy to fuel contraction, or through interference with the ability of Ca2+ to stimulate actin and myosin to contract.
=== Pharmacokinetics === Hydroxychloroquine has similar pharmacokinetics to chloroquine, with rapid gastrointestinal absorption, large distribution volume, and elimination by the kidneys; Tmax is 2–4.5 hours. Cytochrome P450 enzymes (CYP2D6, 2C8, 3A4 and 3A5) metabolize hydroxychloroquine to N-desethylhydroxychloroquine. Both agents also inhibit CYP2D6 activity and may interact with other medications that depend on this enzyme.
== History == Anti-U1 RNP antibodies were first described in the early 1970s during studies of patients with mixed connective tissue disease. In 1972, rheumatologist Dr, Gordon Sharp and colleagues identified antibodies directed against extractable nuclear antigens (ENAs) in patients who had symptoms of several autoimmune connective tissue diseases. Their work helped establish mixed connective tissue disease (MCTD) as a distinct clinical syndrome and made anti-U1 RNP antibodies an important laboratory discovery in rheumatology. The discovery of anti-U1 RNP antibodies also improved the understanding of autoimmune connective tissue disease. Before these antibodies were identified, many patients with overlapping symptoms were difficult to classify because their conditions shared characteristics of several different autoimmune disorders. Identifying anti-U1 RNP antibodies gave healthcare physicians another way to recognize patterns of disease and support the diagnosis of mixed connective tissue disease. Although the antibodies are not exclusive to MCTD, they remain one of the most characteristic scientific findings associated with the condition. Since their discovery, advances in immunology and laboratory testing have improved the ability to detect anti-U1 RNP antibodies. Early testing methods were time-consuming and performed mainly in research laboratories, but newer techniques such as enzyme-linked immunosorbent assays (ELISA), immunoblotting, and multiplex immunoassays have made testing faster and more widely available.
Sources: en.wikipedia.org
SR9009 is a synthetic compound investigated as an agonist of the nuclear receptors REV-ERBα and REV-ERBβ. It is used in preclinical research on circadian rhythm and metabolism. It is not an approved drug.
No. It has no approved medical indication, and human safety and efficacy data are limited. It appears in research chemical markets and is banned by some sports authorities.
Natural ligands include heme and certain metabolites; SR9009 is a synthetic small molecule with higher potency and selectivity in some assays. Its effects depend on cell type and timing. It is not a naturally occurring compound.
SR9009 is a synthetic research compound that binds and modulates the nuclear receptors REV-ERBα and REV-ERBβ. It is used in laboratory studies of circadian biology and metabolism, not as an approved medicine. It is also known by the informal name Stenabolic.